-40%
5KW Wind Turbine MPPT Charge Controller 48V-220V 240V Regulator with Dump load
$ 686.39
- Description
- Size Guide
Description
FEATURES: Perfect protection function:Battery overcharge, over discharge, anti-reverse protection; wind turbine current limiting, brake automatically and brake manually protection; PV anti-charge, anti-reverse protection; lightning protection and so on. The optional dry contact signal output function: According to the actual needs of the battery, the dry contact signal will output when the battery voltage reaches the set voltage. The optional temperature compensation function: According to the change of the ambient temperature, the charging control voltage can be adjusted to charge the battery effectively. The optional off-line storage module: In the remote areas without network coverage and the use of computer inconvenience, you can use the storage function of the off-line storage module to view the history of the system running data ( data recorded within a year). Optional MPPT Charging Function: Real-time monitoring of wind turbine voltage and tracking the maximum voltage and current value (VI), so that wind and solar hybrid system for charging the battery by maximum power.SPECIFICATIONS:
Model
WW
5
0-48-240
Type
Buck
Wind Turbine Input
Rated input power
5
kW
Rated input voltage
280Vdc
Input voltage range
0~320Vdc
Start charge voltage
60Vdc (factory default,40Vdc~320Vdc settable)
Rated input current
13A
Brake by hand
Keep press the button for 5s to unload completely, and then recover by hand.
Switch
“
ON
”
the brake switch
Brake by over current
15Adc (factory default,0~15A settable)Unload completely when reached the set current, and recover automatically after working 10mins.
Brake by overvoltage
320Vdc (Factory default), PWM unload step by step once reached the set unload voltage, and it will unload completely if the voltage rise 20Vdc more.
Brake by over wind speed (optional)
1
8
m/s (0-30m/s settable),Unload completely when reached the set wind speed, and recover automatically after working 10mins.
Brake by over rotational Speed (optional)
500r/min (factory default,0~1000r/min settable)Unload completely when reached the set rotational speed, and recover automatically after working 10mins.
Charge Parameters (optional)
Rated battery voltage
48Vdc
Output Parameters
Rated output voltage
48Vdc
Start unload voltage
56Vdc (factory default,44Vdc~64Vdc settable)
Complete unload voltage
60Vdc
(factory default,add 4V to the start unload voltage)
Max. Output current
63
A
General Parameters
Rectifier mode
Uncontrolled rectifier
Display mode
LCD
Display information
DC output voltage, wind turbine voltage/current/power.
For those with charge control function, Battery voltage is showed as well.
Monitoring Contents
Real-time display: DC output voltage, wind turbine voltage/current/power.
For those with charge control function, Battery voltage is showed as well.
Parameter setting: Output overvoltage point, wind turbine over current point, wind turbine start voltage, and wind turbine manual brake button.
Lightning protection
YES
Conversion efficiency
≥9
2
%
Static loss
<
5W
Ambient temperature
-20℃
~
+40℃
Humidity
0~90%
, No condensing
Noise
≤65dB
Cooling mode
Forced air cooling
Installation mode
Wall-mounted
Cover protection class
IP42
Product dimension (W*H*D)
360×4
4
0×195mm
Product net weight
15.5kg
Dump load dimension (W*H*D)
400×390×210mm
Dump load net weight
13kg
Note:
Part of parameters can be adjusted according to customer
’
s specific demand.
Fault Type
Description
Possible reasons and solutions
No display on LCD
The connection between the battery and the controller is not tight
Check the wiring, and reconnect it.
DC breaker is not on between battery and controller
Turn on the breaker
Low battery voltage
The system parameters are not matched correctly. Recheck the label and parameters on the machine.
The battery doesn’t work. Change a new one.
B
attery is connected in wrong polarity to battery input
terminals.
Need change the internal fuse in controller, and reconnect the battery.
No charging
The connection cable between wind turbine and controller is loose.
Reconnect and fix the cables.
Wind turbine output voltage ha
s
n’t reached the charging voltage,
Check whether the system voltage is reasonable.
Wind turbine is in “Brake” status
Wait the wind turbine recover if it brakes automatically.
Press the
button
for 5s to release the brake status if it brakes by hand.
Battery is already fully charged.
Check if
the battery voltage has reached its output overvoltage.
Name
Icon
Status
Wind Turbine
Rotate means wind turbine works normally
Brake by hand
Battery
Charging
Fully charged. flickering for over voltage, stop flickering when it recover from over voltage
Flickering means over -discharge
Browse button
Press it to enter next LCD display.
Press it for 5s to enter the brake status
Press it for another 5s to recover charging status.
Dump load indicator light
Red light is
on
means the machine is on unload status or brake status.
The light is off when it works normally.